| Sign In | Join Free | My benadorassociates.com | 
 | 
Brand Name : YOUCii
Model Number : UC8523B
Place of Origin : China
MOQ : 1pcs
Price : negotiate a price
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 5 pcs+ per year
Delivery Time : 2 weed
Packaging Details : cartons
Sensor Element : InGaAs
Power Range : + 5 ~ -70 dBm 0~60 dB
Relative Accuracy – Return Loss : ± 0.4 dB
Absolute Power Accuracy : ± 0.2 dB
Interface : RS232
Operation Temperature : 0~ +40℃
Recalibration Period : 2 years
Weight : 3.5 kg
UC8523 Insert Return Loss Meter Optical Communication Testing Equipment
Specification
| Model # | UC8523B+UC88201 | 
| Sensor Element | InGaAs | 
| Operation Wavelength Range | 1310 / 1550 nm | 
| Power Range | + 5 ~ -80 dBm | 
| Return Loss Range | 0~70 dB | 
| Application Fiber Type | Standard SM | 
| Relative Accuracy – Return Loss | ± 0.4 dB | 
| Absolute Power Accuracy | ± 0.2 dB | 
| Relative Accuracy – Insertion Loss | < 0.02 dB Typical | 
| Interface | RS232 | 
| Power | 100 ~ 240 V AC | 
| Operation Temperature | 0~ +40℃ | 
| Storage Temperature | -30~+80℃ | 
| Recalibration Period | 2 years | 
| Dimensions | 245mm W×105mm H×320mm D | 
| Weight | 3.5 kg | 
An overview of the
    UC8523B DUAL LIGHT SOURCE PLUG LOSS INSTRUMENT IS A BENCHTOP, LIQUID CRYSTAL DISPLAY, SINGLE LIGHT SOURCE OUTLET (FC/APC ADAPTER), MEASURING POWER PLUG LOSS, back loss AND DIRECT measurement of OPTICAL POWER INSTRUMENT.
    The instrument is SUITABLE for the test of optical communication components, installation inspection, especially the measurement of the connecting plug of light cable. The system can be built in any two fixed wavelength light sources.
User Interface Description
Front Panel of the host
 The optical output interface is the FC/APC interface

Rear Panel of the host

The power supply requirements
    The UC8523B complies with overvoltage Level II regulations. The operating voltage is 100 ~ 240V AC voltage, the frequency range is 48 ~ 66Hz, the operating voltage is 115V, the maximum consumption current is 230mA; When the operating voltage is 230V, the maximum consumption current is 120mA.
USB port
    The USB interface is a standard 4-core B-type interface, which can be connected to UC8523 and PC, and the instrument can be controlled by monitoring software.
USB connection cable
    The length of the USB cable cannot exceed 5 m. Otherwise, only a third-party USB peripheral extender can be used. Generally, the maximum extension length can reach 50 m.
 RS232 serial port
    The serial port parameters of the instrument are set to a fixed value. The serial port parameter Settings of the computer must match the instrument parameter Settings.

|   | 
| RS232 Insert Return Loss Meter Optical Communication Testing Equipment Images | 
 UC8523 Insert Return Loss Meter 1310Nm 1550Nm Dual Wavelength
                                                                                    
                        
                        
                        
                                                            UC8523 Insert Return Loss Meter 1310Nm 1550Nm Dual Wavelength
                                                    
                        
                     1.0pm Laser Scanning Spectrometer With Output Power 13 DBm Easy To Operate
                                                                                    
                        
                        
                        
                                                            1.0pm Laser Scanning Spectrometer With Output Power 13 DBm Easy To Operate
                                                    
                        
                     Two Channels Laser Scanning Spectrometer ±5 Pm Typ 24 Hrs At Constant Temperatur
                                                                                    
                        
                        
                        
                                                            Two Channels Laser Scanning Spectrometer ±5 Pm Typ 24 Hrs At Constant Temperatur
                                                    
                        
                     1525nm Laser Scanning Spectrometer With 2 Probes Optical Communication Detection
                                                                                    
                        
                        
                        
                                                            1525nm Laser Scanning Spectrometer With 2 Probes Optical Communication Detection
                                                    
                        
                     SMO Fiber Optical Return Loss Meter By Light Source External With Probe
                                                                                    
                        
                        
                        
                                                            SMO Fiber Optical Return Loss Meter By Light Source External With Probe
                                                    
                        
                     60dB Optical Return Loss Meter 2/3/4/5 Multiwavelength Loss Recovery Instrument
                                                                                    
                        
                        
                        
                                                            60dB Optical Return Loss Meter 2/3/4/5 Multiwavelength Loss Recovery Instrument
                                                    
                        
                     10G Four Channel Multi Rate Error Meter 9.953/10.3125G BERT
                                                                                    
                        
                        
                        
                                                            10G Four Channel Multi Rate Error Meter 9.953/10.3125G BERT
                                                    
                        
                     The Wavelength Range Of O Band Laser Scanning Spectrometer Is 1260~1360nm
                                                                                    
                        
                        
                        
                                                            The Wavelength Range Of O Band Laser Scanning Spectrometer Is 1260~1360nm
                                                    
                        
                     Dual Wavelength Insertion Loss Instrument Single Light Source Outlet
                                                                                    
                        
                        
                        
                                                            Dual Wavelength Insertion Loss Instrument Single Light Source Outlet
                                                    
                        
                     Dual Wavelength Insert / Return Loss Meter With LCD Display
                                                                                    
                        
                        
                        
                                                            Dual Wavelength Insert / Return Loss Meter With LCD Display